BACKGROUND/AIMS: To compare event-based methods for estimating the incidence of glaucoma progression using optical coherence tomography (OCT) and automated perimetry and to assess agreement between structural and functional tests for detecting glaucoma progression.



METHODS: Functional progression of glaucoma was estimated by guided progression analysis (GPA) using a Humphrey field analyzer (HFA), and structural progression was assessed by OCT and defined as the decrease in retinal nerve fiber layer thickness based on test-retest variability data of previous reports on clock-hour and quadrant maps. The level of agreement between structural and functional progression was evaluated using kappa statistics.



RESULTS: Fifty eyes of 50 patients with open-angle glaucoma were enrolled in this retrospective study. The incidence of visual field progression estimated by GPA was 18%. The occurrence of structural progression assessed by OCT ranged from 18 to 68%. The more stringent OCT progression criterion using a quadrant map showed the best agreement with HFA GPA (ĸ = 0.423) and detected perimetric progression with high specificity, while the less stringent OCT criterion considering any clock hour showed the lowest agreement with functional progression (ĸ = 0.098).



CONCLUSION: OCT progression criteria based on test-retest variability showed moderate agreement with perimetric progression, and more stringent criteria showed better agreement with functional progression than less stringent ones.
MeSH

DOI
10.1159/000339597
PMID
22846640
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Ophthalmology
Ajou Authors
안, 재홍  |  양, 홍석  |  이, 마빈
Full Text Link
Files in This Item:
There are no files associated with this item.
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse