Cited 0 times in Scipus Cited Count

Placement of retrievable self-expandable metallic stents with barbs into patients with obstructive prostate cancer.

DC Field Value Language
dc.contributor.authorSong, HY-
dc.contributor.authorKim, CS-
dc.contributor.authorJeong, IG-
dc.contributor.authorYoo, D-
dc.contributor.authorKim, JH-
dc.contributor.authorNam, DH-
dc.contributor.authorBae, JI-
dc.contributor.authorPark, JH-
dc.date.accessioned2014-05-30T05:40:06Z-
dc.date.available2014-05-30T05:40:06Z-
dc.date.issued2013-
dc.identifier.issn0938-7994-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/10289-
dc.description.abstractOBJECTIVES: To evaluate the technical feasibility and clinical effectiveness of retrievable self-expandable metallic stents with barbs in patients with obstructive prostate cancer.



METHODS: Retrievable self-expandable metallic stents with eight barbs each were inserted into eight consecutive patients with obstructive prostate cancer. Patient ages ranged from 55 to 76 years (mean, 69 years). All eight patients had previously received hormone therapy, and three had undergone palliative transurethral prostatectomy. Stents were removed using a 21-F stent removal set if they caused complications.



RESULTS: Stent placement was technically successful and well tolerated in all patients. One had severe incontinence, which improved spontaneously, and two had gross haematuria, which disappeared spontaneously within 4 days. Peak urine flow rates and post-void residual urine volumes 1 month after stent placement were 5.6-10.2 ml/s (mean, 8.3 ml/s), and 5-45 ml (mean, 27 ml), respectively. During a mean follow-up of 192 days (range, 39-632 days), one patient required stent removal after 232 days because of stone formation within the stent. No further intervention was required because the mass improved after stent removal.



CONCLUSIONS: These preliminary results suggest that retrievable stents with eight barbs are both feasible to place and effective in patients with obstructive prostate cancer.
-
dc.language.isoen-
dc.subject.MESHAged-
dc.subject.MESHDevice Removal-
dc.subject.MESHEquipment Design-
dc.subject.MESHEquipment Failure Analysis-
dc.subject.MESHFeasibility Studies-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMetals-
dc.subject.MESHMiddle Aged-
dc.subject.MESHProstatic Neoplasms-
dc.subject.MESHStents-
dc.subject.MESHTreatment Outcome-
dc.subject.MESHUreteral Obstruction-
dc.titlePlacement of retrievable self-expandable metallic stents with barbs into patients with obstructive prostate cancer.-
dc.typeArticle-
dc.identifier.pmid22983316-
dc.contributor.affiliatedAuthor배, 재익-
dc.type.localJournal Papers-
dc.identifier.doi10.1007/s00330-012-2650-8-
dc.citation.titleEuropean radiology-
dc.citation.volume23-
dc.citation.number3-
dc.citation.date2013-
dc.citation.startPage780-
dc.citation.endPage785-
dc.identifier.bibliographicCitationEuropean radiology, 23(3). : 780-785, 2013-
dc.identifier.eissn1432-1084-
dc.relation.journalidJ009387994-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse