The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study.

DC Field Value Language
dc.contributor.authorHa, SR-
dc.contributor.authorKim, SH-
dc.contributor.authorHan, JS-
dc.contributor.authorYoo, SH-
dc.contributor.authorJeong, SC-
dc.contributor.authorLee, JB-
dc.contributor.authorYeo, IS-
dc.date.accessioned2014-06-02T04:51:32Z-
dc.date.available2014-06-02T04:51:32Z-
dc.date.issued2013-
dc.identifier.issn2005-7806-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/10339-
dc.description.abstractPURPOSE: The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns.



MATERIALS AND METHODS: Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simulate masticatory force, loads of 280 N were applied from three directions (vertical, at a 45° angle, and horizontal). To simulate maximum bite force, a load of 700 N was applied vertically to the crowns. Maximum principal stress (MPS) was determined for each model, loading condition, and position.



RESULTS: In the maximum bite force simulation test, the MPSs on all crowns observed around the shoulder region and loading points. The compressive stresses were located in the shoulder region of the veneer-zirconia interface and at the occlusal region. In the test simulating masticatory force, the MPS was concentrated around the loading points, and the compressive stresses were located at the 3 mm height lingual shoulder region, when the load was applied horizontally. MPS increased in the shoulder region as the shoulder height increased.



CONCLUSION: This study suggested that reinforced shoulder play an essential role in the success of the zirconia restoration, and veneer fracture due to occlusal loading can be prevented by proper core design, such as shoulder.
-
dc.language.isoen-
dc.titleThe influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study.-
dc.typeArticle-
dc.identifier.pmid23755346-
dc.identifier.urlhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675293/-
dc.subject.keywordDental crowns-
dc.subject.keywordDental prosthesis designs-
dc.subject.keywordFinite element analyses-
dc.subject.keywordZirconia-
dc.contributor.affiliatedAuthor하, 승룡-
dc.type.localJournal Papers-
dc.identifier.doi10.4047/jap.2013.5.2.187-
dc.citation.titleThe journal of advanced prosthodontics-
dc.citation.volume5-
dc.citation.number2-
dc.citation.date2013-
dc.citation.startPage187-
dc.citation.endPage197-
dc.identifier.bibliographicCitationThe journal of advanced prosthodontics, 5(2). : 187-197, 2013-
dc.identifier.eissn2005-7814-
dc.relation.journalidJ020057806-