Cited 0 times in Scipus Cited Count

The relationship between intravascular ultrasound-derived percent total atheroma volume and fractional flow reserve in the intermediate stenosis of proximal or middle left anterior descending coronary artery

DC Field Value Language
dc.contributor.advisor탁, 승제-
dc.contributor.author김, 웅걸-
dc.date.accessioned2015-11-03T05:07:05Z-
dc.date.available2015-11-03T05:07:05Z-
dc.date.issued2015-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/11891-
dc.description.abstractIt remains undefined whether the atherosclerotic disease extent of the conductive vessel (expressed as Intravascular ultrasound [IVUS]-derived percent total atheroma volume [%TAV]), correlates with functional severity of intermediate stenosis of left anterior descending artery (LAD). An IVUS study and fractional flow reserve (FFR) measurements performed in 130 patients with coronary angiographic intermediate stenosis of proximal or middle LAD. %TAV was calculated as the percentage of total vessel volume occupied by total atheroma volume on IVUS. A significant correlation was observed between %TAV and FFR (r=-0.71, p<0.001). Minimal lumen area (MLA) correlated moderately with FFR (r=0.54, p<0.001). The independent predictors of FFR<0.8 were %TAV (odds ratio [OR]:1.29, 95% confidence interval [CI]=1.18-1.40, p<0.001) and MLA (OR:0.37, 95%CI=0.16-0.85, p=0.019). A receiver-operating characteristic curve suggested

%TAV≥39.0% (sensitivity 85%, specificity 83% and area under curve [AUC]=0.90) and MLA≤2.6mm2 (sensitivity 72%, specificity 70% and AUC=0.75) as the best cut-off values for FFR<0.8. Forty-eight point five (48.5%) of total studied lesions (63/130) showed %TAV≥39.0%. Eighty-four point four (84.4%) of lesions (38/45) with %TAV≥39.0% and MLA ≤2.6mm2, and 72.2% of lesions (13/18) with % TAV≥39.0% and MLA>2.6 mm2, FFR was less than 0.8. Volumetric quantification of the atherosclerotic disease extent of the coronary artery, expressed as IVUS-derived %TAV, showed a strong correlation with FFR. Not only the segmental luminal narrowing but also the total plaque

burden of conductive artery are major determinants for the presence of myocardial ischemia in intermediate stenosis of LAD.
-
dc.description.tableofcontentsⅠ. INTRODUCTION 1

Ⅱ. MATERIALS AND METHODS 2

1. Study population 2

2. Quantitative coronary angiographic analysis 2

3. IVUS imaging and analysis 3

4. FFR measurement 4

5. Statistical analysis 5

Ⅲ. RESULTS 6

1. Baseline characteristics 6

2. FFR and QCA parameters 7

3. FFR and IVUS parameters 7

Ⅳ. DISCUSSION 16

REFERENCES 20

국문요약 23
-
dc.language.isoen-
dc.titleThe relationship between intravascular ultrasound-derived percent total atheroma volume and fractional flow reserve in the intermediate stenosis of proximal or middle left anterior descending coronary artery-
dc.title.alternative좌전 하행지 관상동맥 중증도 협착 병변 에서 혈관내 초음파 이용하여 측정한 total plaque volume 과 심근분획 혈류 예비력 사이의 상관관계 : Percent total plaque volume 과 심근분획 혈류 예비력 사이의 상관관계-
dc.typeThesis-
dc.identifier.urlhttp://dcoll.ajou.ac.kr:9080/dcollection/jsp/common/DcLoOrgPer.jsp?sItemId=000000020518-
dc.subject.keywordFractional flow reserve-
dc.subject.keywordIntravascular ultrasound-
dc.subject.keywordPercent total atheroma volume-
dc.subject.keyword심근분획 혈류 예비력-
dc.subject.keyword혈관내 초음파-
dc.subject.keyword퍼센트 total atheroma volume-
dc.description.degreeDoctor-
dc.contributor.department대학원 의학과-
dc.contributor.affiliatedAuthor김, 웅걸-
dc.date.awarded2015-
dc.type.localTheses-
dc.citation.date2015-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
Appears in Collections:
Theses > School of Medicine / Graduate School of Medicine > Doctor
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.