Cited 0 times in Scipus Cited Count

Development of high performance liquid chromatography-ultraviolet detection method for screening mebendazole, clorsulon, diaveridine, and tolfenamic acid in animal-based food samples.

DC Field Value Language
dc.contributor.authorKang, YP-
dc.contributor.authorYu, J-
dc.contributor.authorHuh, Y-
dc.contributor.authorOh, JH-
dc.contributor.authorKwon, CH-
dc.contributor.authorLee, SJ-
dc.contributor.authorEe, JW-
dc.contributor.authorKim, GT-
dc.contributor.authorLee, JG-
dc.contributor.authorLee, J-
dc.contributor.authorPark, JH-
dc.contributor.authorKim, YS-
dc.contributor.authorKwon, SW-
dc.date.accessioned2015-11-17-
dc.date.available2015-11-17-
dc.date.issued2014-
dc.identifier.issn1942-7603-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/11979-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/11979-
dc.description.abstractThis study focused on the detection and validation of the residues of the four veterinary drugs, mebendazole, clorsulon, diaveridine, and tolfenamic acid, using high performance liquid chromatography (HPLC) and an ultraviolet (UV) detector. Utilizing C18 column as a stationary phase and applying appropriate mobile phases to each analysis according to the properties of the analytes, target compounds in food samples were successfully detected and separated within 15-50 min. Additionally, in order to optimize detection, liquid-liquid extraction (LLE) and purification steps were established to minimize the endogenous peaks and their interferences. The method was validated through testing of linearity, accuracy, precision, the limit of detection (LOD) and the limit of quantification (LOQ). The LOQ levels of the four drugs were lower than the maximum residual limit, and the coefficient of determination (R(2) ) was over 0.99. The recovery results ranged from 82.3-105.2%, 79.3-83.3%, 79.4-86.0%, and 81.7-88.5% with relative standard deviations lower than 20% for mebendazole, clorsulon, diaveridine, and tolfenamic acid, respectively, corresponding to the CODEX guideline. This proposed method reduces costs and enables easier application in rural or remote areas where testing facilities or instruments often are unavailable.-
dc.formatapplication/pdf-
dc.language.isoen-
dc.subject.MESHAnimals-
dc.subject.MESHChromatography, High Pressure Liquid-
dc.subject.MESHFood Analysis-
dc.subject.MESHLimit of Detection-
dc.subject.MESHMebendazole-
dc.subject.MESHPyrimidines-
dc.subject.MESHVeterinary Drugs-
dc.subject.MESHortho-Aminobenzoates-
dc.titleDevelopment of high performance liquid chromatography-ultraviolet detection method for screening mebendazole, clorsulon, diaveridine, and tolfenamic acid in animal-based food samples.-
dc.typeArticle-
dc.identifier.pmid23576386-
dc.contributor.affiliatedAuthor김, 유선-
dc.type.localJournal Papers-
dc.identifier.doi10.1002/dta.1467-
dc.citation.titleDrug testing and analysis-
dc.citation.volume6-
dc.citation.number3-
dc.citation.date2014-
dc.citation.startPage246-
dc.citation.endPage256-
dc.identifier.bibliographicCitationDrug testing and analysis, 6(3). : 246-256, 2014-
dc.identifier.eissn1942-7611-
dc.relation.journalidJ019427603-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Biochemistry & Molecular Biology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse