A simple intraoperative method for assessment of pedicle screw trajectory using contrast medium injection.

Authors
Jeon, CH  | Chung, NS
Citation
Journal of spinal disorders & techniques, 27(1). : E14-E19, 2014
Journal Title
Journal of spinal disorders & techniques
ISSN
1536-06521539-2465
Abstract
STUDY DESIGN: Retrospective radiologic study. OBJECTIVE: To introduce a novel

method for intraoperative verification of the pedicle screw pathway using

contrast medium injection. SUMMARY OF BACKGROUND DATA: Various surgical

techniques and equipments, such as, mechanical probing, intraoperative

fluoroscopy, computer-assisted navigation system, and neurophysiological

monitoring have been devised to assist accurate pedicle screw placement. However,

pedicle screw misplacement remains of considerable concern, even to experienced

spine surgeons. MATERIALS AND METHODS: Fifty pedicle screws placed using the

devised contrast medium technique in 39 consecutive patients were included. The

authors used a contrast medium injection to verify pedicle screw tracts when

pedicle wall violation was doubtful with conventional methods. Contrast medium

(Iopamidol) was injected through the prepared screw path under fluoroscopic view.

The screw path preparation was deemed successful when contrast medium was

contained within the prepared screw tract. Pedicle screw placements were

interpreted by postoperative computed tomography. RESULTS: Intraoperative

verifications of pedicle screw paths using contrast medium technique showed that

6 of the 50 (12%) screw paths were disrupted, and these paths were redirected.

Posteoperative computed tomography evaluations showed that 39 of the 50 (78%)

screws were correctly placed. Of the 11 misplaced screws, 9 (18%) were

interpreted as exhibiting cortical encroachment, and 2 (4%) as exhibiting mild

frank penetration. CONCLUSIONS: The intraoperative injection of contrast medium

provides a simple, fast, safe, and reliable means of verifying pedicle screw

tract, when pedicle wall violation is doubtful.
MeSH

DOI
10.1097/BSD.0b013e3182886fd7
PMID
23429313
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Orthopedic Surgery
Ajou Authors
전, 창훈  |  정, 남수
Full Text Link
Files in This Item:
There are no files associated with this item.
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse