Cited 0 times in
Accurate registration of cone-beam computed tomography scans to 3-dimensional facial photographs.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nahm, KY | - |
dc.contributor.author | Kim, Y | - |
dc.contributor.author | Choi, YS | - |
dc.contributor.author | Lee, J | - |
dc.contributor.author | Kim, SH | - |
dc.contributor.author | Nelson, G | - |
dc.date.accessioned | 2016-11-22T02:24:54Z | - |
dc.date.available | 2016-11-22T02:24:54Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 0889-5406 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/12962 | - |
dc.description.abstract | INTRODUCTION: Registering a 3-dimensional (3D) facial surface scan to a cone-beam
computed tomography (CBCT) scan has various advantages. One major advantage is to compensate for the inaccuracy of the CBCT surface data. However, when registering CBCT and 3D facial scans, changes in facial expression, spatial soft-tissue changes, and differences in the patient's positioning can decrease the accuracy of the registration. In this study, we introduce a new 3D facial scanner that is combined with a CBCT apparatus. Our goal was to evaluate the registration accuracy of CBCT and 3D facial scans, which were taken with the shortest possible time between them. METHODS: The experiment was performed with 4 subjects. Each patient was instructed to hold as still as possible while the CBCT scan was taken, followed immediately by the 3D facial surface scan. The images were automatically registered with software. The accuracy was measured by determining the degree of agreement between the soft-tissue surfaces of the CBCT and the 3D facial images. RESULTS: The average surface discrepancy between the CBCT facial surface and 3D facial surface was 0.60 mm (SD, 0.12 mm). Registration accuracy was also visually verified by toggling between the images of the CBCT and 3D facial surface scans while rotating the registered images. CONCLUSIONS: Registration of consecutively taken CBCT and 3D facial images resulted in reliable accuracy. | - |
dc.language.iso | en | - |
dc.subject.MESH | Cone-Beam Computed Tomography | - |
dc.subject.MESH | Face | - |
dc.subject.MESH | Facial Bones | - |
dc.subject.MESH | Facial Expression | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Image Processing, Computer-Assisted | - |
dc.subject.MESH | Imaging, Three-Dimensional | - |
dc.subject.MESH | Optical Imaging | - |
dc.subject.MESH | Photography | - |
dc.subject.MESH | Posture | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.subject.MESH | Software | - |
dc.title | Accurate registration of cone-beam computed tomography scans to 3-dimensional facial photographs. | - |
dc.type | Article | - |
dc.identifier.pmid | 24485741 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0889540613009736 | - |
dc.contributor.affiliatedAuthor | 남, 경연 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1016/j.ajodo.2013.10.018 | - |
dc.citation.title | American journal of orthodontics and dentofacial orthopedics | - |
dc.citation.volume | 145 | - |
dc.citation.number | 2 | - |
dc.citation.date | 2014 | - |
dc.citation.startPage | 256 | - |
dc.citation.endPage | 264 | - |
dc.identifier.bibliographicCitation | American journal of orthodontics and dentofacial orthopedics, 145(2). : 256-264, 2014 | - |
dc.identifier.eissn | 1097-6752 | - |
dc.relation.journalid | J008895406 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.