Cited 0 times in Scipus Cited Count

Ultrasound Features of Middle Cervical Sympathetic Ganglion.

DC Field Value Language
dc.contributor.authorShin, JE-
dc.contributor.authorBaek, JH-
dc.contributor.authorHa, EJ-
dc.contributor.authorChoi, YJ-
dc.contributor.authorChoi, WJ-
dc.contributor.authorLee, JH-
dc.date.accessioned2017-04-04T10:46:48Z-
dc.date.available2017-04-04T10:46:48Z-
dc.date.issued2015-
dc.identifier.issn0749-8047-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/13781-
dc.description.abstractOBJECTIVES: To evaluate the feasibility of ultrasound (US) detection of the middle cervical sympathetic ganglion (CSG).

MATERIALS AND METHODS: We examined 52 consecutive patients with 104 bilateral middle CSGs. We identified middle CSG according to our sonographic assessment criteria. After finding oval-shaped hypoechoic structure on transverse scan, we verified a continuous, hypoechoic line connecting the bulbous structure at both sides. The basic US characteristics were evaluated using the size, location, relationship to the common carotid artery, and relationship to the inferior thyroidal artery.

RESULTS: The middle CSG was identified in 41% (43/104). The mean size of the middle CSG was 3.8±1.5 mm in width, 1.9±0.7 mm in height, and 8.7±3.2 mm in length. They were primarily located at the C6 level (41/43, 95%). Regarding the relationship with common carotid artery, 88% (38/43) were lateral type and 12% (5/43) were medial type. Regarding the relationship with the inferior thyroid artery, 34% (15/43) were anterior type, 26% (11/43) were posterior type, and 40% (17/43) were unable to access the relationship.

DISCUSSION: Direct visualization of middle CSG based on the understanding of both its location and US features may reduce complications and improve the accuracy of US-guided neck procedures.
-
dc.language.isoen-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHCervical Vertebrae-
dc.subject.MESHFemale-
dc.subject.MESHGanglia, Sympathetic-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHNeck Pain-
dc.subject.MESHUltrasonics-
dc.subject.MESHUltrasonography-
dc.subject.MESHYoung Adult-
dc.titleUltrasound Features of Middle Cervical Sympathetic Ganglion.-
dc.typeArticle-
dc.identifier.pmid25411859-
dc.identifier.urlhttps://www.ncbi.nlm.nih.gov/pmc/articles/pmid/26576124/-
dc.contributor.affiliatedAuthor하, 은주-
dc.type.localJournal Papers-
dc.identifier.doi10.1097/AJP.0000000000000184-
dc.citation.titleThe Clinical journal of pain-
dc.citation.volume31-
dc.citation.number10-
dc.citation.date2015-
dc.citation.startPage909-
dc.citation.endPage913-
dc.identifier.bibliographicCitationThe Clinical journal of pain, 31(10). : 909-913, 2015-
dc.identifier.eissn1536-5409-
dc.relation.journalidJ007498047-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Files in This Item:
25411859.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.