Cited 0 times in
Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, JB | - |
dc.contributor.author | Kwak, HJ | - |
dc.contributor.author | Lee, KC | - |
dc.contributor.author | Lee, SR | - |
dc.contributor.author | Lee, SY | - |
dc.contributor.author | Kim, JY | - |
dc.date.accessioned | 2018-05-04T00:24:17Z | - |
dc.date.available | 2018-05-04T00:24:17Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 0913-8668 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/14832 | - |
dc.description.abstract | OBJECTIVE: Each supraglottic airway requires different anesthetic depth because it has a specific structure and different compressive force in the oropharyngeal cavity. We designed the study to compare the effect-site concentration (Ce) of remifentanil in 50 % of patients (EC50) for successful insertion of the i-gel second-generation supraglottic airway device with that for laryngeal mask airway (LMA) insertion during target-controlled infusion (TCI) of propofol. METHODS: Forty-one female patients were randomized to the i-gel group (n = 20) or the LMA group (n = 21). Anesthesia was induced with propofol Ce of 5 mug/ml and the predetermined remifentanil Ce, and the i-gel or LMA was inserted 5 min later. The remifentanil Ce was estimated by modified Dixon's up-and-down method (initial concentration: 3.0 ng/ml, step size: 0.5 ng/ml). The patient's response to device insertion was classified as either "success (no movement)" or "failure (movement)". RESULTS: Using the Dixon's up-and-down method, EC50 of remifentanil Ce for the i-gel (1.58 +/- 0.41 ng/ml) was significantly lower than that for LMA (2.25 +/- 0.55 ng/ml) (p = 0.038). Using isotonic regression, EC50 (83 % CI) of remifentanil in the i-gel group [1.50 (1.37-1.80) ng/ml] was statistically lower than that in the LMA group [2.00 (1.82-2.34) ng/ml]. EC95 (95 % CI) of remifentanil in the i-gel group [2.38 (1.48-2.50) ng/ml] was statistically lower than that in the LMA group [3.35 (2.58-3.48) ng/ml]. CONCLUSIONS: We found that EC50 of remifentanil Ce for i-gel insertion (1.58 ng/ml) was significantly lower than that for LMA insertion (2.25 ng/ml) in female patients during propofol TCI without neuromuscular blockade. | - |
dc.language.iso | en | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Anesthesia | - |
dc.subject.MESH | Anesthetics, Intravenous | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Laryngeal Masks | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Neuromuscular Blockade | - |
dc.subject.MESH | Piperidines | - |
dc.subject.MESH | Pressure | - |
dc.subject.MESH | Propofol | - |
dc.title | Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia | - |
dc.type | Article | - |
dc.identifier.pmid | 26758073 | - |
dc.contributor.affiliatedAuthor | 이, 숙영 | - |
dc.contributor.affiliatedAuthor | 김, 종엽 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1007/s00540-015-2133-6 | - |
dc.citation.title | Journal of anesthesia | - |
dc.citation.volume | 30 | - |
dc.citation.number | 3 | - |
dc.citation.date | 2016 | - |
dc.citation.startPage | 377 | - |
dc.citation.endPage | 383 | - |
dc.identifier.bibliographicCitation | Journal of anesthesia, 30(3). : 377-383, 2016 | - |
dc.embargo.liftdate | 9999-12-31 | - |
dc.embargo.terms | 9999-12-31 | - |
dc.identifier.eissn | 1438-8359 | - |
dc.relation.journalid | J009138668 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.