Cited 0 times in Scipus Cited Count

Decalcification using ethylenediaminetetraacetic acid for clear microstructure imaging of cochlea through optical coherence tomography

DC Field Value Language
dc.contributor.authorLee, J-
dc.contributor.authorKim, K-
dc.contributor.authorWijesinghe, RE-
dc.contributor.authorJeon, D-
dc.contributor.authorLee, SH-
dc.contributor.authorJeon, M-
dc.contributor.authorJang, JH-
dc.date.accessioned2018-05-04T00:24:22Z-
dc.date.available2018-05-04T00:24:22Z-
dc.date.issued2016-
dc.identifier.issn1083-3668-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/14846-
dc.description.abstractThe aim of this study was to analyze the effectiveness of decalcification using ethylenediaminetetraacetic acid (EDTA) as an optical clearing method to enhance the depth visibility of internal soft tissues of cochlea. Ex vivo mouse and guinea pig cochlea samples were soaked in EDTA solutions for decalcification, and swept source optical coherence tomography (OCT) was used as imaging modality to monitor the decalcified samples consecutively. The monitored noninvasive cross-sectional images showed that the mouse and guinea pig cochlea samples had to be decalcified for subsequent 7 and 14 days, respectively, to obtain the optimal optical clearing results. Using this method, difficulties in imaging of internal cochlea microstructures of mice could be evaded. The obtained results verified that the depth visibility of the decalcified ex vivo samples was enhanced.-
dc.language.isoen-
dc.subject.MESHAnimals-
dc.subject.MESHCochlea-
dc.subject.MESHEdetic Acid-
dc.subject.MESHGuinea Pigs-
dc.subject.MESHHistological Techniques-
dc.subject.MESHImage Processing, Computer-Assisted-
dc.subject.MESHMale-
dc.subject.MESHMice-
dc.subject.MESHMice, Inbred ICR-
dc.subject.MESHTomography, Optical Coherence-
dc.titleDecalcification using ethylenediaminetetraacetic acid for clear microstructure imaging of cochlea through optical coherence tomography-
dc.typeArticle-
dc.identifier.pmid26979048-
dc.contributor.affiliatedAuthor장, 정훈-
dc.type.localJournal Papers-
dc.identifier.doi10.1117/1.JBO.21.8.081204-
dc.citation.titleJournal of biomedical optics-
dc.citation.volume21-
dc.citation.number8-
dc.citation.date2016-
dc.citation.startPage81204-
dc.citation.endPage81204-
dc.identifier.bibliographicCitationJournal of biomedical optics, 21(8). : 81204-81204, 2016-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn1560-2281-
dc.relation.journalidJ010833668-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Otolaryngology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse