Cited 0 times in Scipus Cited Count

Evaluation of the reduction rate of radon concentration, following free measurement of indoor radon and the alarm device installation.

DC Field Value Language
dc.contributor.authorCho, Y-
dc.contributor.authorJin, Y-
dc.contributor.authorLee, SB-
dc.contributor.authorKang, D-
dc.contributor.authorLee, C-
dc.date.accessioned2018-06-28T04:05:33Z-
dc.date.available2018-06-28T04:05:33Z-
dc.date.issued2016-
dc.identifier.issn2288-9167-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/15387-
dc.description.abstractThis study aimed at providing fundamental information for development of governmental policy on radon management, investigated the radon levels of residential homes nationwide. It also suggested the necessity for policy development which focuses on management of the degree of harm through the installation of radon alarm devices and radon reduction consulting for homes with radon readings in excess of recommended threshold. Results showed that the radon level of the subjects of this study, 1,167 houses, was 97.3 ± 65.8 Bq/m3. Regionally, Seoul had the highest level, while Jeju had the lowest. In the first round of the investigation, the number of houses, with radon level which exceeded the recommended threshold, 148 Bq/m3, was 171. However, as a result of the radon alarm installation and radon reduction consultation, the indoor radon level of 137 households decreased to less than the recommended threshold. In the second round of the investigation, 80% of the households, the radon concentration of which exceeded the current recommended threshold in the first round, appeared to maintain their radon concentration below the recommended threshold. As a result of the communication about radon's harmfulness and the installation of the radon alarm device for recognition of harmful environments. It could be deduced from this result that the communication about harm contributes to the reduction of radon.-
dc.language.isoko-
dc.titleEvaluation of the reduction rate of radon concentration, following free measurement of indoor radon and the alarm device installation.-
dc.title.alternative실내 라돈 무료측정 및 알람기 설치 후의 저감율 평가-
dc.typeArticle-
dc.subject.keywordRadon alarm device-
dc.subject.keywordRadon concentration-
dc.subject.keywordRadon evaluation-
dc.subject.keywordReduce rate-
dc.contributor.affiliatedAuthor강, 대용-
dc.type.localJournal Papers-
dc.identifier.doi10.15250/joie.2016.15.2.109-
dc.citation.titleJournal of Odor and Indoor Environment-
dc.citation.volume15-
dc.citation.number2-
dc.citation.date2016-
dc.citation.startPage109-
dc.citation.endPage118-
dc.identifier.bibliographicCitationJournal of Odor and Indoor Environment, 15(2). : 109-118, 2016-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn2288-923X-
dc.relation.journalidJ022889167-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Medical Humanities & Social Medicine
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.