Cited 0 times in Scipus Cited Count

US Elastography Using Carotid Artery Pulsation May Increase the Diagnostic Accuracy for Thyroid Nodules with US-Pathology Discordance

DC Field Value Language
dc.contributor.authorCho, YJ-
dc.contributor.authorHa, EJ-
dc.contributor.authorHan, M-
dc.contributor.authorChoi, JW-
dc.date.accessioned2018-08-24T01:48:55Z-
dc.date.available2018-08-24T01:48:55Z-
dc.date.issued2017-
dc.identifier.issn0301-5629-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/15914-
dc.description.abstractThis study evaluated the diagnostic performance of ultrasound elastography (USE) using carotid arterial pulsation and determined the reproducibility of USE for thyroid nodules. A total of 148 patients with 173 thyroid nodules participated. The mean elasticity contrast index (ECI) was significantly higher in malignant nodules (3.1 +/- 1.5) than in benign nodules (1.7 +/- 0.8) (p < 0.001). When a cut-off ECI value of 3.5 was used, the diagnostic accuracy (78.6%) of gray-scale ultrasound (US) + ECI was the highest compared with that of the gray-scale US (76.9%) and ECI (67.1%). In 16 of 43 nodules (37.2%) with US-pathology, discordance could be correctly reclassified as benign (8 of 11) or malignant (8 of 32). The intra-class correlation coefficient for inter-observer agreement was 0.96, and those for intra-observer agreement were 0.97 and 0.98. Thyroid nodules with ECI values of >3.5 may have an additional value to increase the diagnostic accuracy for nodules with US-pathology discordance with reproducible results.-
dc.language.isoen-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHCarotid Arteries-
dc.subject.MESHDiagnosis, Differential-
dc.subject.MESHElasticity Imaging Techniques-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHImage Processing, Computer-Assisted-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHObserver Variation-
dc.subject.MESHProspective Studies-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHThyroid Gland-
dc.subject.MESHThyroid Nodule-
dc.subject.MESHYoung Adult-
dc.titleUS Elastography Using Carotid Artery Pulsation May Increase the Diagnostic Accuracy for Thyroid Nodules with US-Pathology Discordance-
dc.typeArticle-
dc.identifier.pmid28528019-
dc.contributor.affiliatedAuthor하, 은주-
dc.contributor.affiliatedAuthor한, 미란-
dc.contributor.affiliatedAuthor최, 진욱-
dc.type.localJournal Papers-
dc.identifier.doi10.1016/j.ultrasmedbio.2017.04.007-
dc.citation.titleUltrasound in medicine & biology-
dc.citation.volume43-
dc.citation.number8-
dc.citation.date2017-
dc.citation.startPage1587-
dc.citation.endPage1595-
dc.identifier.bibliographicCitationUltrasound in medicine & biology, 43(8). : 1587-1595, 2017-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn1879-291X-
dc.relation.journalidJ003015629-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse