Randomized, noninferiority study between video versus hand ultrasound with wet foam dressing materials to simulate B-lines in lung ultrasound: A CONSORT-compliant article

Authors
Park, EJ  | Yoon, YT | Hong, CK | Ha, YR | Ahn, JH
Citation
Medicine, 96(30). : e7642-e7642, 2017
Journal Title
Medicine
ISSN
0025-79741536-5964
Abstract
BACKGROUND: This study evaluated the efficacy of a teaching method using simulated B-lines of hand ultrasound with a wet foam dressing material.
METHODS: This prospective, randomized, noninferiority study was conducted on emergency medical technician students without any relevant training in ultrasound. Following a lecture including simulated (SG) or real video clips (RG) of B-lines, a posttest was conducted and a retention test was performed after 2 months. The test consisted of questions about B-lines in 40 randomly mixed video clips (20 simulated and 20 real videos) with 4 answer scores (R-1 [the correct answer score for the real video clips] vs S-1 [the correct answer score for the simulated video clips] in the posttest, R-2 [the correct answer score for the real video clips] vs S-2 [the correct answer score for the simulated video clips] in the retention test).
RESULTS: A total of 77 and 73 volunteers participated in the posttest (RG, 38: SG, 39) and retention test (RG, 36: SG, 37), respectively. There was no significant (P > .05) difference in scores of R-1, S-1, R-2, or S-2 between RG and SG. The mean score differences between RG and SG were -0.6 (95% confidence interval [CI]: -1.49 to 0.11) in R-1, -0.1 (95% CI: -1.04 to 0.86) in S-1, 0 (95% CI: -1.57 to 1.50) in R-2, and -0.2 (95% CI: -1.52 to 0.25) in S-2. The mean differences and 95% CIs for all parameters fell within the noninferiority margin of 2 points (10%).
CONCLUSION: Simulated B-lines of hand ultrasound with a wet foam dressing material were not inferior to real B-lines. They were effective for teaching and simulations.
TRIAL REGISTRATION: The study was registered with the Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp (KCT0002144).
MeSH

DOI
10.1097/MD.0000000000007642
PMID
28746228
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Emergency Medicine
Ajou Authors
박, 은정  |  안, 정환
Full Text Link
Files in This Item:
28746228.pdfDownload
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse