Cited 0 times in Scipus Cited Count

N-butyl-2 cyanoacrylate (NBCA) embolus in the graft portal vein after portosystemic collateral embolization in liver transplantation recipient: what is the clinical significance?

DC Field Value Language
dc.contributor.authorJang, HY-
dc.contributor.authorKim, KW-
dc.contributor.authorKwon, JH-
dc.contributor.authorKwon, HJ-
dc.contributor.authorKim, B-
dc.contributor.authorSeo, N-
dc.contributor.authorLee, J-
dc.contributor.authorSong, GW-
dc.contributor.authorLee, SG-
dc.date.accessioned2018-08-24T01:49:32Z-
dc.date.available2018-08-24T01:49:32Z-
dc.date.issued2017-
dc.identifier.issn0284-1851-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/16021-
dc.description.abstractBackground An N-butyl-2 cyanoacrylate (NBCA) embolus in the graft portal vein was frequently observed after an intraoperative embolization of portosystemic collaterals performed to prevent portal steal in liver transplant (LT) recipients. The radiological and clinical features of NBCA emboli have not yet been described. Purpose To describe radiological and clinical features of NBCA embolus in graft portal vein after portosystemic collateral embolization in LT recipients. Material and Methods A total of 165 consecutive LT recipients who had undergone intraoperative NBCA embolization of varix were found in single institution's computerized databases of a clinical cohort of LT. Patients were evaluated for NBCA emboli (categorized into major and minor emboli according to location) on first postoperative computed tomography (CT). All electronic medical records and radiologic studies including follow-up was evaluated to determine any radiological and clinical abnormality associated with NBCA embolus. Results NBCA emboli were found in 24% (39/165) of recipients. Although most patients had minor emboli (77%, 30/39) without remarkable ultrasonography (US) abnormalities, seven (78%) of nine recipients with major emboli showed intraluminal echogenic lesions in graft portal vein on grayscale US, and five of them (71%) showed partial portal flow obstruction, although none exhibited any abnormality on contrast-enhanced US. Recipients with NBCA portal emboli showed no significant clinical abnormalities and were discharged safely. NBCA embolus eventually disappeared mostly within six months (82%, 32/39). Conclusion NBCA emboli are frequently observed after portosystemic collateral embolization in LT recipients and are not associated with poor clinical outcome. They may mimic ordinary thromboemboli on US.-
dc.language.isoen-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHEmbolism-
dc.subject.MESHEmbolization, Therapeutic-
dc.subject.MESHEnbucrilate-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHLiver Transplantation-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPortal Vein-
dc.subject.MESHPostoperative Complications-
dc.subject.MESHTomography, X-Ray Computed-
dc.subject.MESHUltrasonography-
dc.subject.MESHYoung Adult-
dc.titleN-butyl-2 cyanoacrylate (NBCA) embolus in the graft portal vein after portosystemic collateral embolization in liver transplantation recipient: what is the clinical significance?-
dc.typeArticle-
dc.identifier.pmid28273742-
dc.contributor.affiliatedAuthor김, 보현-
dc.type.localJournal Papers-
dc.identifier.doi10.1177/0284185117693460-
dc.citation.titleActa radiologica (Stockholm, Sweden : 1987)-
dc.citation.volume58-
dc.citation.number11-
dc.citation.date2017-
dc.citation.startPage1326-
dc.citation.endPage1333-
dc.identifier.bibliographicCitationActa radiologica (Stockholm, Sweden : 1987), 58(11). : 1326-1333, 2017-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn1600-0455-
dc.relation.journalidJ002841851-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse