Cited 0 times in
Effect of distal protection device on the microvascular integrity in acute myocardial infarction during primary percutaneous coronary intervention.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoon, MH | - |
dc.contributor.author | Tahk, SJ | - |
dc.contributor.author | Choi, SY | - |
dc.contributor.author | Choi, TY | - |
dc.contributor.author | Choi, BJ | - |
dc.contributor.author | Choi, JH | - |
dc.contributor.author | Yoo, SY | - |
dc.contributor.author | Ahn, SG | - |
dc.contributor.author | Zheng, ZG | - |
dc.contributor.author | Hwang, GS | - |
dc.contributor.author | Shin, JH | - |
dc.date.accessioned | 2011-03-28T05:49:51Z | - |
dc.date.available | 2011-03-28T05:49:51Z | - |
dc.date.issued | 2006 | - |
dc.identifier.issn | 1346-9843 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/1981 | - |
dc.description.abstract | BACKGROUND: The use of a distal protection device during primary percutaneous coronary intervention (PCI) in acute myocardial infarction (AMI) may preserve the microvascular integrity of the myocardium.
METHODS AND RESULTS: A total of 58 consecutive patients with AMI, who had undergone primary PCI within 24 h after onset, were enrolled (30 patients with the PercuSurge GuardWire System, 28 without). The coronary flow velocity reserve was not different between the 2 groups. In patients with a distal protection device, the post-PCI Thrombolysis In Myocardial Infarction myocardial perfusion grades (TMP) were more favorable (TMP 0/1: 13.3%, TMP 2: 23.3%, TMP 3: 63.4% vs TMP 0/1: 35.7%, TMP 2: 35.7%, TMP 3: 28.6%, p=0.023). These patients also exhibited lower basal and hyperemic microvascular resistance index levels (4.33+/-2.22 vs 5.55+/-2.36 mmHg . cm(-1) . s, p=0.047; 2.39+/-1.40 vs 3.14+/-1.36 mmHg . cm(-1) . s, p=0.045, respectively), and longer basal diastolic deceleration time (679+/-273 vs 519+/-289 ms, p=0.035) after PCI. CONCLUSION: Distal protection with the PercuSurge GuardWire system may effectively preserve the microvascular integrity of the myocardium during primary PCI in AMI patients. | - |
dc.language.iso | en | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Angioplasty, Balloon, Coronary | - |
dc.subject.MESH | Blood Flow Velocity | - |
dc.subject.MESH | Coronary Vessels | - |
dc.subject.MESH | Equipment and Supplies | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Microcirculation | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Myocardial Infarction | - |
dc.title | Effect of distal protection device on the microvascular integrity in acute myocardial infarction during primary percutaneous coronary intervention. | - |
dc.type | Article | - |
dc.identifier.pmid | 16998260 | - |
dc.identifier.url | http://joi.jlc.jst.go.jp/JST.JSTAGE/circj/70.1284?from=PubMed | - |
dc.contributor.affiliatedAuthor | 윤, 명호 | - |
dc.contributor.affiliatedAuthor | 탁, 승제 | - |
dc.contributor.affiliatedAuthor | 최, 소연 | - |
dc.contributor.affiliatedAuthor | 최, 병주 | - |
dc.contributor.affiliatedAuthor | 황, 교승 | - |
dc.contributor.affiliatedAuthor | 신, 준한 | - |
dc.type.local | Journal Papers | - |
dc.citation.title | Circulation journal | - |
dc.citation.volume | 70 | - |
dc.citation.number | 10 | - |
dc.citation.date | 2006 | - |
dc.citation.startPage | 1284 | - |
dc.citation.endPage | 1289 | - |
dc.identifier.bibliographicCitation | Circulation journal, 70(10). : 1284-1289, 2006 | - |
dc.identifier.eissn | 1347-4820 | - |
dc.relation.journalid | J013469843 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.