Cited 0 times in Scipus Cited Count

Single screw type of lag screw results higher reoperation rate in the osteosynthesis of basicervical hip fracture

DC Field Value Language
dc.contributor.authorKim, JT-
dc.contributor.authorHa, YC-
dc.contributor.authorPark, CH-
dc.contributor.authorYoo, JI-
dc.contributor.authorKim, TY-
dc.date.accessioned2022-11-11T04:09:33Z-
dc.date.available2022-11-11T04:09:33Z-
dc.date.issued2020-
dc.identifier.issn0949-2658-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/22541-
dc.description.abstractBACKGROUND: Basicervical hip fractures are relatively rare with greater biomechanical instability compared to the other types of hip fractures. Several studies have reported ambivalent surgical outcomes of basicervical hip fractures. The purpose of this multicenter study was to analyze surgical outcomes of basicervical hip fractures according to the fixation type of proximal femur and lag screw type.

METHODS: Among 3220 hip fractures, 145 were classified as basicervical hip fractures. Of those, 106 patients treated with osteosynthesis were included to analyze the surgical complications according to fixation type of proximal femur: sliding hip screw(SHS) and cephalomedullary nail (CMN) groups. Surgical complications including the excessive displacement of fracture and the occurrence of reoperation were evaluated at the final follow up. We further evaluated surgical complications according to lag screw type with subgroup analysis in CMN group: single screw type, blade type and two integrated screw type.

RESULTS: Ten patients (9.4%) sustained surgical complications (5 excessive displacements and 5 reoperations). For fixation type of proximal femur, SHS group showed higher tendency of excessive displacement despite no statistical difference between the two groups (p = 0.060). For lag screw type with subgroup analysis in CMN group, single screw type showed statistically high rates of reoperation compared to the other types of lag screw (p = 0.022).

CONCLUSION: Basicervical hip fractures treated with osteosynthesis resulted to high rates of surgical complications in this study. However, they could be drastically reduced if CMN with blade type or two integrated screw type were used in the osteosynthesis of basicervical hip fractures.
-
dc.language.isoen-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHBone Screws-
dc.subject.MESHEquipment Design-
dc.subject.MESHFemale-
dc.subject.MESHFracture Fixation, Internal-
dc.subject.MESHHip Fractures-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHReoperation-
dc.titleSingle screw type of lag screw results higher reoperation rate in the osteosynthesis of basicervical hip fracture-
dc.typeArticle-
dc.identifier.pmid30851995-
dc.contributor.affiliatedAuthorKim, JT-
dc.type.localJournal Papers-
dc.identifier.doi10.1016/j.jos.2019.02.010-
dc.citation.titleJournal of orthopaedic science-
dc.citation.volume25-
dc.citation.number1-
dc.citation.date2020-
dc.citation.startPage152-
dc.citation.endPage155-
dc.identifier.bibliographicCitationJournal of orthopaedic science, 25(1). : 152-155, 2020-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn1436-2023-
dc.relation.journalidJ009492658-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Orthopedic Surgery
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse