Cited 0 times in Scipus Cited Count

Development of a compact X-band linear accelerator system mounted on an O-arm rotating gantry for radiation therapy

Authors
Kim, S | Lee, YS | Kim, GJ | Lee, JH | Kim, IS | Shin, KY | Seol, Y | Oh, Y | Kang, YN | Hwang, J | Shin, JS | Kim, A | Kim, J  | Kim, JI
Citation
The Review of scientific instruments, 92(2). : 024103-024103, 2021
Journal Title
The Review of scientific instruments
ISSN
0034-67481089-7623
Abstract
A compact X-band linear accelerator (LINAC) system equipped with a small and lightweight magnetron was constructed to develop a high-precision image-guided radiotherapy system. The developed LINAC system was installed in an O-ring gantry where cone-beam computed tomography (CBCT) was embedded. When the O-arm gantry is rotated, an x-ray beam is stably generated, which resulted from the stable transmission of radio frequency power into the X-band LINAC system. Quality assurance (QA) tests, including mechanical and dosimetry checks, were carried out to ensure safety and operation performance according to the American Association of Physicists in Medicine's TG-51, 142, an international standard protocol established by accredited institutions. In addition, delivery QA of the radiotherapy planning system was conducted to verify intensity-modulated radiotherapy techniques. Therefore, it was demonstrated that the developed X-band LINAC system mounted on the O-arm gantry proved to be valid and reliable for potential use in CBCT image-guided radiation therapy.
MeSH

DOI
10.1063/5.0030271
PMID
33648097
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiation Oncology
Ajou Authors
김, 지나
Files in This Item:
There are no files associated with this item.
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse