Cited 0 times in Scipus Cited Count

Consumer-grade sleep trackers are still not up to par compared to polysomnography

DC Field Value Language
dc.contributor.authorKim, K-
dc.contributor.authorPark, DY-
dc.contributor.authorSong, YJ-
dc.contributor.authorHan, S-
dc.contributor.authorKim, HJ-
dc.date.accessioned2023-02-27T07:12:44Z-
dc.date.available2023-02-27T07:12:44Z-
dc.date.issued2022-
dc.identifier.issn1520-9512-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/24850-
dc.description.abstractPURPOSE: Although polysomnography (PSG) is the gold standard for monitoring sleep, it has many limitations. We aimed to prospectively determine the validity of wearable sleep-tracking devices and smartphone applications by comparing the data to that of PSGs. METHODS: Patients who underwent one night of attended PSG at a single institution from January, 2015 to July 2019 were recruited. Either a sleep application or wearable device was used simultaneously while undergoing PSG. Nine smartphone applications and three wearable devices were assessed. RESULTS: We analyzed the results of 495 cases of smartphone applications and 170 cases of wearables by comparing each against PSG. None of the tested applications were able to show a statistically significant correlation between sleep efficiency, durations of wake time, light sleep or deep sleep with PSG. Snore time correlated well in both of the two applications which provided such information. Deep sleep duration and WASO measured by two of the three wearable devices correlated significantly with PSG. Even after controlling for transition count and moving count, the correlation indices of the wearables did not increase, suggesting that the algorithms used by the wearables were not largely affected by tossing and turning. CONCLUSIONS: Most of the applications tested in this study showed poor validity, while wearable devices mildly correlated with PSG. An effective use for these devices may be as a tool to identify the change seen in an individual's sleep patterns on a day-to-day basis, instead of as a method of detecting absolute measurements.-
dc.language.isoen-
dc.subject.MESHActigraphy-
dc.subject.MESHHumans-
dc.subject.MESHPolysomnography-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSleep-
dc.subject.MESHWearable Electronic Devices-
dc.titleConsumer-grade sleep trackers are still not up to par compared to polysomnography-
dc.typeArticle-
dc.identifier.pmid34741243-
dc.subject.keywordActigraphy-
dc.subject.keywordPolysomnography-
dc.subject.keywordSleep-
dc.subject.keywordSmartphone-
dc.contributor.affiliatedAuthorPark, DY-
dc.contributor.affiliatedAuthorKim, HJ-
dc.type.localJournal Papers-
dc.identifier.doi10.1007/s11325-021-02493-y-
dc.citation.titleSleep & breathing-
dc.citation.volume26-
dc.citation.number4-
dc.citation.date2022-
dc.citation.startPage1573-
dc.citation.endPage1582-
dc.identifier.bibliographicCitationSleep & breathing, 26(4). : 1573-1582, 2022-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn1522-1709-
dc.relation.journalidJ015209512-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Otolaryngology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.