Cited 0 times in
Delayed aortic regurgitation after TEVAR procedure: a case report
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, SJ | - |
dc.contributor.author | Lee, S | - |
dc.contributor.author | Son, JA | - |
dc.contributor.author | Hyun, S | - |
dc.contributor.author | Kim, DJ | - |
dc.contributor.author | Lim, SH | - |
dc.contributor.author | Hong, YS | - |
dc.date.accessioned | 2023-03-24T06:27:15Z | - |
dc.date.available | 2023-03-24T06:27:15Z | - |
dc.date.issued | 2022 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/25172 | - |
dc.description.abstract | BACKGROUND: Acute aortic regurgitation (AR) is uncommon condition and usually results in an emergent situation because the left ventricle does not adapt quickly due to a sudden increase in end-diastolic volume caused by the regurgitant flow. Thoracic endovascular aortic repair (TEVAR) is a procedure that places a stent-graft on the lesion of thoracic aorta through a minimally invasive approach. CASE PRESENTATION: Here we report that a catheter-induced aortic valve injury associated with TEVAR can cause delayed AR, exemplified by the case of a patient who developed acute AR 42 months after TEVAR. For this, aortic valve replacement was performed and the patient was discharged without complications. CONCLUSION: Our results demonstrate that when a catheter-related procedure is performed around the aortic valve, slight injury of the valve can cause aortic insufficiency even 3 years after surgery. Consequently, when performing a catheter-related procedure around the aortic valve, special attention is always required. | - |
dc.language.iso | en | - |
dc.subject.MESH | Aorta, Thoracic | - |
dc.subject.MESH | Aortic Aneurysm, Thoracic | - |
dc.subject.MESH | Aortic Diseases | - |
dc.subject.MESH | Aortic Valve Insufficiency | - |
dc.subject.MESH | Blood Vessel Prosthesis | - |
dc.subject.MESH | Blood Vessel Prosthesis Implantation | - |
dc.subject.MESH | Endovascular Procedures | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Stents | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Delayed aortic regurgitation after TEVAR procedure: a case report | - |
dc.type | Article | - |
dc.identifier.pmid | 36564804 | - |
dc.identifier.url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9789620 | - |
dc.subject.keyword | Aortic regurgitation | - |
dc.subject.keyword | Catheter induced injury | - |
dc.subject.keyword | Thoracic endovascular aortic repair (TEVAR) | - |
dc.contributor.affiliatedAuthor | Lee, S | - |
dc.contributor.affiliatedAuthor | Kim, DJ | - |
dc.contributor.affiliatedAuthor | Lim, SH | - |
dc.contributor.affiliatedAuthor | Hong, YS | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1186/s13019-022-02083-3 | - |
dc.citation.title | Journal of cardiothoracic surgery | - |
dc.citation.volume | 17 | - |
dc.citation.number | 1 | - |
dc.citation.date | 2022 | - |
dc.citation.startPage | 336 | - |
dc.citation.endPage | 336 | - |
dc.identifier.bibliographicCitation | Journal of cardiothoracic surgery, 17(1). : 336-336, 2022 | - |
dc.identifier.eissn | 1749-8090 | - |
dc.relation.journalid | J017498090 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.