Cited 0 times in Scipus Cited Count

Inter-observer agreement on the interpretation of capsule endoscopy findings based on capsule endoscopy structured terminology: a multicenter study by the Korean Gut Image Study Group.

Authors
Jang, BI | Lee, SH | Moon, JS | Cheung, DY | Lee, IS | Kim, JO | Cheon, JH | Park, CH | Byeon, JS | Park, YS | Shim, KN | Kim, YS | Kim, KJ | Lee, KJ  | Ryu, JK | Chang, DK | Chun, HJ | Choi, MG
Citation
Scandinavian journal of gastroenterology, 45(3). : 370-374, 2010
Journal Title
Scandinavian journal of gastroenterology
ISSN
0036-55211502-7708
Abstract
OBJECTIVE: Capsule endoscopy (CE) is a novel investigation for the diagnosis of small-bowel disease but its interpretation is highly subjective. We studied the inter-observer agreement and accuracy of the interpretation of CE findings based on capsule endoscopy structured terminology (CEST).



MATERIAL AND METHODS: Fifty-six CE video clips were collected from eight university hospitals in South Korea and were independently reviewed by 13 gastroenterology experts and 10 trainees. All investigators recorded their findings based on CEST. To determine the accuracy of individual viewers, we defined the 'gold standard' as a joint review by four experts.



RESULTS: The 56 CE video clips included five normal cases, 19 cases of protruding lesions, 21 cases of depressed lesions, three cases of flat lesions, one case of abnormal mucosa, six cases with blood in the lumen, and one case of stenotic lumen. The overall mean accuracies for the experts and trainees were 74.3% +/- 22.6% and 61.7% +/- 25.4%, respectively. The overall accuracy for the trainee group was significantly lower than that for the expert group (P < 0.001), especially in normal, tumor, venous structure, and ulcer cases. The accuracies of the two groups varied with the CE findings. The accuracies were higher in cases with more prominent intraluminal changes (e.g. active small-bowel bleeding, ulcer, tumor, stenotic lumen). In contrast, subtle mucosal lesions, such as erosion, angioectasia, and diverticulum, had lower accuracies. The mean kappa values for the experts and trainees were 0.61 (range 0.39-0.97) and 0.46 (range 0.17-0.66), respectively.



CONCLUSIONS: Our results showed that there was substantial agreement between experts and moderate agreement between trainees. In order to achieve higher accuracies and better inter-observer agreement, we need not only more experience with CE but also consensus regarding CEST terminology.
MeSH

DOI
10.3109/00365520903521574
PMID
20148733
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Gastroenterology
Ajou Authors
이, 광재
Full Text Link
Files in This Item:
There are no files associated with this item.
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse