Abstract
Purpose: The relationship between retear that may occur after rotator cuff repair and patient satisfaction is not well established. This study aimed to determine whether the types and size of the retear evaluated by computed tomography arthrography (CTA) influenced patient satisfaction. We also analyzed the patient factors that could affect patient satisfaction. Patients and methods: A total of 50 patients who were diagnosed with rotator cuff retear after undergoing arthroscopic rotator cuff repair were included in this study. All the patients were dichotomously classified into the satisfactory or dissatisfactory groups according to the patients’ self-classifications. CTA was used to assess the attachment status of the footprint, detect retear on the medial side of the footprint of the repaired cuff, and determine the retear size. Demographic factors, including sex, age, occupation, dominant upper extremity, duration of pain, presence of diabetes mellitus, trauma history, history of ipsilateral shoulder surgery, repair technique, worker’s compensation status, and functional shoulder score, were investigated. Results: Thirty-nine patients were classified into the satisfactory group and 11 patients were classified into the dissatisfactory group. There were no differences in age, sex, occupation, dominant hand, duration of pain, presence of diabetes mellitus, trauma history, history of ipsilateral shoulder surgery, repair technique, worker’s compensation, and duration of follow-up between the two groups. However, the postoperative American Shoulder and Elbow Surgeon (ASES) score (P < 0.01), visual analog scale (VAS) pain level (P < 0.01), anteroposterior (AP) length (P < 0.01), and area of the retear site (P < 0.01) were significantly different. Conclusion: The AP length and area of the retear site estimated using CTA were confirmed as the significant risk factors for dissatisfaction. However, the type of repaired rotator cuff judged by the attachment status of the footprint did not correlate with patient satisfaction. In addition, the postoperative VAS pain scale and ASES score was correlated with patient satisfaction.
Keywords

MeSH

DOI
10.1186/s12891-023-06617-1
PMID
37312057
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Orthopedic Surgery
Ajou Authors
최, 완선  |  한, 경진
Full Text Link
Files in This Item:
37312057.pdfDownload
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse