Cited 0 times in Scipus Cited Count

Treatment of unstable peritrochanteric femoral fractures using a 95 degrees angled blade plate.

DC Field Value Language
dc.contributor.authorYoo, MC-
dc.contributor.authorCho, YJ-
dc.contributor.authorKim, KI-
dc.contributor.authorKhairuddin, M-
dc.contributor.authorChun, YS-
dc.date.accessioned2011-07-01T01:51:12Z-
dc.date.available2011-07-01T01:51:12Z-
dc.date.issued2005-
dc.identifier.issn0890-5339-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/3161-
dc.description.abstractOBJECTIVE: To clarify the efficacy of a 95-degree angled blade plate fixation in the treatment of unstable peritrochanteric fractures of the femur.



DESIGN: Retrospective, clinical study.



SETTING: University hospital.



PATIENTS: Thirty-nine consecutive patients with peritrochanteric femoral fractures were followed for a minimum of 12 months. There were 29 subtrochanteric fractures and 10 intertrochanteric fractures (reverse obliquity pattern) for which the compression hip screw could not be used because of comminution of the trochanteric area and fracture extension to the lateral cortex. The mean age of the patient population at the time of operation was 54 (range, 17-71) years.



INTERVENTION: Open reduction and internal fixation of the pertrochanteric fractures using a 95 degrees angled blade plate.



MAIN OUTCOME MEASUREMENTS: Time to fracture union, operation time, and complications.



RESULTS: Duration of clinical follow-up averaged 26 (range, 12-36) months. The average time to osseous union for those fractures that healed primarily was 19 (range, 13-28) weeks. Two of 39 fractures united with 10 degrees varus deformity, but no corrective surgery was warranted. Limb length discrepancy more than 1.5 cm did not occur. Implant failure before solid bony union occurred in 1 case with a severely comminuted subtrochanteric fracture. Postoperative infection or osteonecrosis of the femoral head did not occur any time throughout the follow-up period.



CONCLUSION: A 95 angled blade plate can be a useful alternative fixation device for the treatment of unstable peritrochanteric femoral fractures.
-
dc.language.isoen-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHBone Plates-
dc.subject.MESHBone Screws-
dc.subject.MESHEquipment Failure Analysis-
dc.subject.MESHFemale-
dc.subject.MESHFemoral Fractures-
dc.subject.MESHFracture Fixation, Internal-
dc.subject.MESHFracture Healing-
dc.subject.MESHHumans-
dc.subject.MESHJoint Instability-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPostoperative Complications-
dc.subject.MESHProsthesis Implantation-
dc.subject.MESHRecovery of Function-
dc.subject.MESHTreatment Outcome-
dc.titleTreatment of unstable peritrochanteric femoral fractures using a 95 degrees angled blade plate.-
dc.typeArticle-
dc.identifier.pmid16314715-
dc.identifier.urlhttp://meta.wkhealth.com/pt/pt-core/template-journal/lwwgateway/media/landingpage.htm?issn=0890-5339&volume=19&issue=10&spage=687-
dc.contributor.affiliatedAuthor전, 영수-
dc.type.localJournal Papers-
dc.citation.titleJournal of orthopaedic trauma-
dc.citation.volume19-
dc.citation.number10-
dc.citation.date2005-
dc.citation.startPage687-
dc.citation.endPage692-
dc.identifier.bibliographicCitationJournal of orthopaedic trauma, 19(10). : 687-692, 2005-
dc.identifier.eissn1531-2291-
dc.relation.journalidJ008905339-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Orthopedic Surgery
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse