Cited 0 times in Scipus Cited Count

Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels

Authors
Ihn, YK | Kim, BS | Jeong, HW | Suh, SH | Won, YD | Lee, YJ | Kim, DJ | Jeon, P | Ryu, CW | Suh, SI | Choi, DS | Choi, SS | Kim, SH | Byun, JS | Rho, J | Song, Y | Jeong, WS  | Hong, N | Baik, SH | Park, JJ | Lim, SM | Kim, JJ | Yoon, W
Citation
Neurointervention, 16(3). : 240-251, 2021
Journal Title
Neurointervention
ISSN
2093-90432233-6273
Abstract
Purpose: To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL). Materials and Methods: Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution. Results: Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, Ihn YK et al. Reference Doses for Interventional Neuroradiology Procedures in Korea and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group. Conclusion: Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs.
Keywords

DOI
10.5469/neuroint.2021.00437
PMID
34695909
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Ajou Authors
정, 우상
Full Text Link
Files in This Item:
34695909.pdfDownload
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse