Cited 0 times in
Side-by-side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Paik, WH | - |
dc.contributor.author | Jung, MK | - |
dc.contributor.author | Kim, DU | - |
dc.contributor.author | Song, TJ | - |
dc.contributor.author | Yang, MJ | - |
dc.contributor.author | Choi, YH | - |
dc.contributor.author | Kim, JS | - |
dc.contributor.author | Lee, MW | - |
dc.contributor.author | Choi, JH | - |
dc.contributor.author | Lee, SH | - |
dc.date.accessioned | 2024-06-19T07:06:56Z | - |
dc.date.available | 2024-06-19T07:06:56Z | - |
dc.date.issued | 2024 | - |
dc.identifier.issn | 0915-5635 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/32512 | - |
dc.description.abstract | Objectives: We aimed to evaluate the efficacy and safety of metal stents compared with plastic stents when bilateral side-by-side stents were deployed for malignant hilar biliary obstruction (MHBO). Methods: Fifty patients with unresectable advanced MHBO were randomly assigned to the metal stent (MS, n = 25) or plastic stent group (PS, n = 25). Fully covered self-expandable metal stents with 6 mm diameter and plastic stents with either 7F straight or double pigtail were used for MS and PS groups, respectively. Time to recurrent biliary obstruction (TRBO) was evaluated as the primary outcome. Results: Both groups had 100% technical success rates; 88% and 76% of clinical success rates were obtained in MS and PS, respectively. Although stent migrations were more frequent in MS than PS (48% vs. 16%, P = 0.02), the mean TRBO was significantly longer in MS (190 days; 95% confidence interval [CI] 121–260 days vs. 96 days; 95% CI 50–141 days, P = 0.02). The placement of plastic stents (hazard ratio 2.42; 95% CI 1.24–4.73; P = 0.01) was the only significant risk factor associated with TRBO in multivariable analysis. The rates of adverse events were similar between the two groups (difference 0%; 95% CI −25% to 25%; P > 0.99). Conclusions: During bilateral side-by-side deployment in MHBO, the use of metal stents appears to be preferable to plastic stents in terms of TRBO, despite a higher frequency of stent migration. | - |
dc.language.iso | en | - |
dc.subject.MESH | Bile Duct Neoplasms | - |
dc.subject.MESH | Cholestasis | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Prosthesis Implantation | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Self Expandable Metallic Stents | - |
dc.subject.MESH | Stents | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Side-by-side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial | - |
dc.type | Article | - |
dc.identifier.pmid | 37612129 | - |
dc.subject.keyword | cholestasis | - |
dc.subject.keyword | endoscopic retrograde cholangiopancreatography | - |
dc.subject.keyword | Klatskin | - |
dc.subject.keyword | palliation | - |
dc.contributor.affiliatedAuthor | Yang, MJ | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1111/den.14669 | - |
dc.citation.title | Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society | - |
dc.citation.volume | 36 | - |
dc.citation.number | 4 | - |
dc.citation.date | 2024 | - |
dc.citation.startPage | 473 | - |
dc.citation.endPage | 480 | - |
dc.identifier.bibliographicCitation | Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society, 36(4). : 473-480, 2024 | - |
dc.embargo.liftdate | 9999-12-31 | - |
dc.embargo.terms | 9999-12-31 | - |
dc.identifier.eissn | 1443-1661 | - |
dc.relation.journalid | J009155635 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.