Cited 0 times in Scipus Cited Count

Psychometric Testing of the Korean Version of the Self-Care of Coronary Heart Disease Inventory Version 3

Authors
Park, JH  | Gwon, SH | Yoon, MH  | Lee, AY | Bae, SH
Citation
Asian nursing research, 18(3). : 238-245, 2024
Journal Title
Asian nursing research
ISSN
1976-13172093-7482
Abstract
Purpose: This methodological study evaluated the psychometric properties of the Self-Care of Coronary Heart Disease Inventory version 3 (SC-CHDI v3) in a Korean context. Methods: The SC-CHDI v3 was translated into Korean following a rigorous translation process. Participants were 452 patients who had experienced coronary heart disease (CHD), all recruited from a tertiary hospital in Korea. Exploratory and confirmatory factor analyses were performed to test construct validity. Concurrent validity was examined by correlating scores from the Korean version of the SC-CHDI v3 with those from the Cardiac Self-Efficacy Scale. Internal consistency was analyzed using Cronbach's alpha and McDonald's omega. Results: The Korean version of the SC-CHDI v3 consists of 21 items, excluding two from the original instrument. The self-care maintenance subscale identified a two-factor structure: “treatment adherence” and “health-promoting behaviors.” The goodness-of-fit indices were satisfied: χ2 = 18.19, p = .110, comparative fit index (CFI) = .97, Tucker-Lewis Index (TLI) = .95, and standardized root mean square residual (SRMR) = .04. The self-care monitoring subscale consisted of a one-dimensional structure (“monitoring behaviors”) and the goodness-of-fit indices were satisfied: χ2 = 19.19, p = .059, CFI = .99, TLI = .99, and SRMR = .04. The self-care management subscales had a two-factor structure of “consulting behaviors” and “problem-solving behaviors.” The goodness-of-fit indices were satisfied: χ2 = 16.44, p = .037, CFI = .99, TLI = .98, and SRMR = .03. Scores from the Cardiac Self-Efficacy Scale showed a positive correlation with the Korean version of SC-CHDI v3 subscales. Reliability estimates were ≥ .80 for all subscales except for the self-care maintenance subscale. Conclusions: The Korean version of the SC-CHDI v3 consists of 21 items in 3 subscales and is a valid and reliable instrument. Therefore, healthcare providers can effectively utilize it to assess the self-care levels of patients with CHD.
Keywords

MeSH

DOI
10.1016/j.anr.2024.07.001
PMID
39038702
Appears in Collections:
Journal Papers > College of Nursing Science / Graduate School of Nursing Sciences > Nursing Science
Journal Papers > School of Medicine / Graduate School of Medicine > Cardiology
Ajou Authors
박, 진희  |  배, 선형  |  윤, 명호
Full Text Link
Files in This Item:
39038702.pdfDownload
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse