Cited 0 times in Scipus Cited Count

Complications in motility PEG placement for hydroxyapatite orbital implant in anophthalmic socket.

Authors
Lee, SY | Jang, JW  | Lew, H | Kim, SJ | Kim, HY
Citation
Japanese journal of ophthalmology, 46(1). : 103-107, 2002
Journal Title
Japanese journal of ophthalmology
ISSN
0021-51551613-2246
Abstract
PURPOSE: In a retrospective study, we evaluated the complications in using the motility peg system (nonsleeved and sleeved) for hydroxyapatite orbital implants in an anophthalmic socket.



METHODS: Drilling for motility peg placement was performed in 265 patients with hydroxyapatite implantation: nonsleeved peg system (n = 191), sleeved peg system (n = 74). A statistical analysis was performed using the chi-square test.



RESULTS: Extrusion rates were significantly lower in the sleeved peg system (10.8%) compared to the nonsleeved peg system (27.2%) (P =.005). The other complications related to motility peg placement were granulation tissue overgrowth (4.2%), hydroxyapatite exposure around peg head (3.0%), and decentered peg (1.9%).



CONCLUSIONS: To minimize peg extrusion, the sleeved peg was better than the nonsleeved peg for use in primary motility peg placement.
MeSH