Cited 0 times in
Cross-calibration of multi-frequency bioelectrical impedance analysis with eight-point tactile electrodes and dual-energy X-ray absorptiometry for assessment of body composition in healthy children aged 6-18 years.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lim, JS | - |
dc.contributor.author | Hwang, JS | - |
dc.contributor.author | Lee, JA | - |
dc.contributor.author | Kim, DH | - |
dc.contributor.author | Park, KD | - |
dc.contributor.author | Jeong, JS | - |
dc.contributor.author | Cheon, GJ | - |
dc.date.accessioned | 2010-12-01T05:23:22Z | - |
dc.date.available | 2010-12-01T05:23:22Z | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 1328-8067 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/371 | - |
dc.description.abstract | BACKGROUND: In diagnosis and treatment of obesity, body composition analysis including percent body fat (%BF) is useful in the clinical setting. Because bioelectrical impedance analysis (BIA) could be used quickly, easily and was non-invasive in clinical setting, the purpose of the present study was to evaluate the usefulness of multi-frequency BIA with eight-point tactile electrodes (MF-BIA8; InBody 720, Biospace) compared with dual-energy X-ray absorptiometry (DXA) in healthy children and adolescents.
METHODS: A total of 166 children and adolescents under 18 (male, n = 86; female, n = 80) were recruited. Height, weight, body mass index (BMI) and Tanner stage were measured for each subject. The body composition such as fat-free mass (FFM), fat mass (FM), and %BF was measured on BIA and DXA and compared. RESULTS: On linear regression analysis, DXA FFM = 1.006(BIA FFM) + 0.554, R(2) = 0.99 and the standard error of the estimate (SEE) was 1.16 kg; DXA FM = 0.971(BIA FM) - 0.596, R(2) = 0.93; SEE, 1.34 kg; and DXA %BF = 0.940(BIA %BF) - 1.026, R(2) = 0.858; SEE, 3.03%. Limit of agreement in FFM, FM, and %BF was 0.7 +/- 2.3 kg, -0.9 +/- 2.9 kg and -2.2 +/- 6.1%, respectively. CONCLUSIONS: Although the %BF was not interchangeable with DXA, MF-BIA8 (InBody 720; Biospace) could be used to measure body composition of children and adolescents in the clinical field because of its high precision. | - |
dc.language.iso | en | - |
dc.subject.MESH | Absorptiometry, Photon | - |
dc.subject.MESH | Adolescent | - |
dc.subject.MESH | Body Composition | - |
dc.subject.MESH | Child | - |
dc.subject.MESH | Electric Impedance | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.title | Cross-calibration of multi-frequency bioelectrical impedance analysis with eight-point tactile electrodes and dual-energy X-ray absorptiometry for assessment of body composition in healthy children aged 6-18 years. | - |
dc.type | Article | - |
dc.identifier.pmid | 19405930 | - |
dc.identifier.url | http://onlinelibrary.wiley.com/resolve/openurl?genre=article&sid=nlm:pubmed&issn=1328-8067&date=2009&volume=51&issue=2&spage=263 | - |
dc.contributor.affiliatedAuthor | 황, 진순 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1111/j.1442-200X.2008.02698.x | - |
dc.citation.title | Pediatrics international | - |
dc.citation.volume | 51 | - |
dc.citation.number | 2 | - |
dc.citation.date | 2009 | - |
dc.citation.startPage | 263 | - |
dc.citation.endPage | 268 | - |
dc.identifier.bibliographicCitation | Pediatrics international, 51(2). : 263-268, 2009 | - |
dc.identifier.eissn | 1442-200X | - |
dc.relation.journalid | J013288067 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.