Cited 0 times in
Study on the Three Dimensional Structure of the Human Ossicle Using Micro CT
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박, 기현 | - |
dc.contributor.author | 문, 성균 | - |
dc.contributor.author | 이, 준호 | - |
dc.contributor.author | 원, 예연 | - |
dc.contributor.author | 백, 명현 | - |
dc.date.accessioned | 2012-01-11T01:27:56Z | - |
dc.date.available | 2012-01-11T01:27:56Z | - |
dc.date.issued | 2003 | - |
dc.identifier.issn | 1225-035X | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/5222 | - |
dc.description.abstract | BACKGROUND AND OBJECTIVES: Conventional studies of the middle ear ossicles give relatively limited information on shape, mechanical strength and 3-dimensional relationship. Recently, Micro CT scanning technology has been applied to analysis of skeletal structures. This study aims to reconstruct the 3-dimensional structure of the ossicles, including length, thickness, strength, and the angle.
MATERIALS AND METHOD: The structures of ossicles obtained from 3 cadavers were analyzed through micro CT by filming the 2-dimensional cross section image running perpendicular to the long axis of the ossicles. The 3-dimensional images were thereby reconstructed for each, and were analyzed using CT-Analyzer(TM) and Ant(TM). Based on the results, the strength, length, and angle of each ossicle were measured. RESULTS: The ratio between the handle of malleus (4.413 mm) and the long process of incus (3.559 mm), which acts as a lever of the middle ear impedance transformer, was 1.24. The volume fraction, indicating relative strengths of ossicles, was higher in the portion close to the articular surface. CONCLUSION: Our preliminary data of the ossicular structure analysed by micro CT scan will be helpful for the elucidation of ossicle's structure and the further development of artificial prosthesis. | - |
dc.format | application/pdf | - |
dc.language.iso | ko | - |
dc.title | Study on the Three Dimensional Structure of the Human Ossicle Using Micro CT | - |
dc.title.alternative | Micro CT를 이용한 사람 이소골의 3차원적 구조에 대한 연구 | - |
dc.type | Article | - |
dc.subject.keyword | Ear ossicles | - |
dc.subject.keyword | Three-dimensional imaging | - |
dc.subject.keyword | Microradiography | - |
dc.subject.keyword | 이소골 | - |
dc.subject.keyword | 미세단층촬영 | - |
dc.subject.keyword | 3차원 영상 | - |
dc.contributor.affiliatedAuthor | 박, 기현 | - |
dc.contributor.affiliatedAuthor | 문, 성균 | - |
dc.contributor.affiliatedAuthor | 이, 준호 | - |
dc.contributor.affiliatedAuthor | 원, 예연 | - |
dc.type.local | Journal Papers | - |
dc.citation.title | Journal of the Korean Otolaryngological Society | - |
dc.citation.volume | 46 | - |
dc.citation.number | 4 | - |
dc.citation.date | 2003 | - |
dc.citation.startPage | 276 | - |
dc.citation.endPage | 281 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Otolaryngological Society, 46(4). : 276-281, 2003 | - |
dc.relation.journalid | J01225035X | - |