Cited 0 times in Scipus Cited Count

Volume Fractionof the Human Pathologic Ossicles Destructed by Cholesteatoma Using Micro-CT

DC Field Value Language
dc.contributor.author박, 기현-
dc.contributor.author문, 성균-
dc.contributor.author조, 민정-
dc.contributor.author이, 진석-
dc.contributor.author윤, 용로-
dc.date.accessioned2012-01-11T23:57:33Z-
dc.date.available2012-01-11T23:57:33Z-
dc.date.issued2004-
dc.identifier.issn1225-035X-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/5228-
dc.description.abstractBACKGROUND AND OBJECTIVES: Conventional studies for the middle ear ossicles destructed by cholesteatoma give relatively limited information on shape, mechanical strength and 3-dimensional relationship. Recently, Micro-CT scanning technology has been applied to analysis of skeletal structure. This study aims to reconstruct the 3-dimensional structure of normal ossicles and destructed ossicles by different cholesteatomas and to compare volume fraction of destructed ossicles with that of normal ossicles.
MATERIALS AND METHOD: 13 pathological ossicles obtained during cholesteatoma surgery were used in this study (2 malleuses and 2 incuses from attic cholesteatoma;1 malleus and 2 incuses from sinus cholesteatoma;2 malleuses and 2 incuses from tensa retraction cholesteatoma; 2 incuses from congenital cholesteatoma). As a control, normal ossicles harvested from cadaveric temporal bone specimens were used. The structure of obtained ossicles was analyzed through Micro-CT (SkySan-1072, Belgium) by filming the 2-dimensional cross section image running perpendicular to the long axis of the ossicles. The 3-dimensional images were thereby reconstructed for each, and were analyzed using CT-Analyzer(TM) and ANTTM. Based on the results, the strength of each ossicle were measured.
RESULTS: The volume fraction, indicating relative strengths of ossicles, was lower in the portion of destructed surface. The pattern of destructed ossicles by cholesteatoma was different according to pathological status of cholesteatoma.
CONCLUSION: Our preliminary data of ossicular structure analyzed by Micro-CT scan will be helpful for elucidation of pathological ossicles in middle ear cholesteatoma and will make a great contribution to research of middle ear cholesteatoma.
-
dc.formatapplication/pdf-
dc.language.isoko-
dc.subject.ddc이소골-
dc.titleVolume Fractionof the Human Pathologic Ossicles Destructed by Cholesteatoma Using Micro-CT-
dc.title.alternativeMico-CT를 이용한 중이 진주종에 의해 파괴된 이소골의 체적비율-
dc.typeArticle-
dc.subject.keywordEar osssicles-
dc.subject.keywordCholeteatoma-
dc.subject.keywordThree-dimensional imaging-
dc.subject.keywordMicroradiography-
dc.subject.keyword진주종-
dc.subject.keyword3차원적 구조-
dc.subject.keyword미세 방사선 사진술-
dc.contributor.affiliatedAuthor박, 기현-
dc.contributor.affiliatedAuthor문, 성균-
dc.contributor.affiliatedAuthor조, 민정-
dc.contributor.affiliatedAuthor이, 진석-
dc.contributor.affiliatedAuthor윤, 용로-
dc.type.localJournal Papers-
dc.citation.titleJournal of the Korean Otolaryngological Society-
dc.citation.volume47-
dc.citation.number5-
dc.citation.date2004-
dc.citation.startPage413-
dc.citation.endPage418-
dc.identifier.bibliographicCitationJournal of the Korean Otolaryngological Society, 47(5). : 413-418, 2004-
dc.relation.journalidJ01225035X-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Otolaryngology
Files in This Item:
Journal of the Korean Otolaryngological Society_47(5)_413-418.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse