Cited 0 times in Scipus Cited Count

The Clinical Experience of Hemodialyzer Reuse

DC Field Value Language
dc.contributor.authorCho, HK-
dc.contributor.authorKim, SJ-
dc.contributor.authorIm, BK-
dc.contributor.authorChung, HJ-
dc.contributor.authorChoi, YI-
dc.contributor.authorMa, KA-
dc.contributor.authorShin, GT-
dc.contributor.authorKim, HS-
dc.contributor.authorKim, DH-
dc.date.accessioned2012-02-23T04:25:11Z-
dc.date.available2012-02-23T04:25:11Z-
dc.date.issued2001-
dc.identifier.issn1225-0015-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/5816-
dc.description.abstractThe major clinical advantages of dialyzer reuse are improved biocompatibility and a decrease in the frequency of the first use syndrome. Dialyzer reuse has made it possible to use biocompatible high flux membranes of the high price. Although dialyzer reuse in chronic hemodialysis patients is commonly practiced in the United States, it is not widely accepted in Korea. At Ajou University Hospital, we have reprocessed dialyzers since March 2000, and here we report our clinical experience for the 1st 8 weeks. We used high flux dialyzers with reprocessing practice in 24 chronic hemodialysis patients. Dialyzer reprocessing was performed by an automated machine(Renatron) using Renalin. We limited reuse upto 20 times, and we were able to reuse dialyzers upto this number in 17 patients. During the study period, no significant complication was observed as a result of the reuse program. Kt/Vurea and urea reduction ratio(URR) were not different between high and low flux dialyzers(1.41±0.29 vs 1.61±0.41 for Kt/Vurea and 66.70±6.40% vs 65.69±5.63% for URR). In contrast, β2microglobulin(β2M) reduction ratio and clearance were greater in high flux dialyzers than low flux dialyzers(p<0.001, -9.52±20.28% vs 42.00±8.61% for ,β2M reduction ratio and 9.54±11.71mL/min vs 48.54±14.33mL/min for β2M clearance). Kt/Vurea, URR, β2M reduction ratio and β2M clearance did not deteriorate with the increasing number of reuse. The predialysis values of β2M decreased by 51% after 19 uses (p<0.001, 37.04±13.39 to 18.98±3.41mg/L). In summary, during the short pilot study period of 8 weeks, no significant clinical complication was encountered as a result of dialyzer reuse, and our results confirmed the effects of high flux dialyzers on removal of β2M.en
dc.formatapplication/pdf-
dc.language.isoko-
dc.titleThe Clinical Experience of Hemodialyzer Reuse-
dc.title.alternative고유량 고효율 혈액투석막 재사용의 임상경험-
dc.typeArticle-
dc.identifier.urlhttps://krcp-ksn.org/journal/view.php?number=4628-
dc.subject.keywordDialyzer reuse-
dc.subject.keywordβ2-microglobulin-
dc.contributor.affiliatedAuthor임, 병국-
dc.contributor.affiliatedAuthor정, 혁준-
dc.contributor.affiliatedAuthor신, 규태-
dc.contributor.affiliatedAuthor김, 흥수-
dc.contributor.affiliatedAuthor김, 도헌-
dc.type.localJournal Papers-
dc.citation.titleThe Korean journal of nephrology-
dc.citation.volume20-
dc.citation.number3-
dc.citation.date2001-
dc.citation.startPage469-
dc.citation.endPage477-
dc.identifier.bibliographicCitationThe Korean journal of nephrology, 20(3). : 469-477, 2001-
dc.relation.journalidJ112250015-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Nephrology
Files in This Item:
The Korean journal of nephrology_20(3)_469-477.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse