Cited 0 times in
Outcomes after unrestricted use of everolimus-eluting and sirolimus-eluting stents in routine clinical practice: a multicenter, prospective cohort study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, DW | - |
dc.contributor.author | Kim, YH | - |
dc.contributor.author | Song, HG | - |
dc.contributor.author | Ahn, JM | - |
dc.contributor.author | Kim, WJ | - |
dc.contributor.author | Lee, JY | - |
dc.contributor.author | Kang, SJ | - |
dc.contributor.author | Lee, SW | - |
dc.contributor.author | Lee, CW | - |
dc.contributor.author | Park, SW | - |
dc.contributor.author | Yun, SC | - |
dc.contributor.author | Her, SH | - |
dc.contributor.author | Hur, SH | - |
dc.contributor.author | Park, JS | - |
dc.contributor.author | Kim, MK | - |
dc.contributor.author | Choi, YS | - |
dc.contributor.author | Kim, HS | - |
dc.contributor.author | Cho, JH | - |
dc.contributor.author | Lee, SG | - |
dc.contributor.author | Park, YW | - |
dc.contributor.author | Jeong, MH | - |
dc.contributor.author | Lee, BK | - |
dc.contributor.author | Lee, NH | - |
dc.contributor.author | Lim, DS | - |
dc.contributor.author | Yoon, J | - |
dc.contributor.author | Seung, KB | - |
dc.contributor.author | Shin, WY | - |
dc.contributor.author | Rha, SW | - |
dc.contributor.author | Kim, KS | - |
dc.contributor.author | Tahk, SJ | - |
dc.contributor.author | Park, BE | - |
dc.contributor.author | Ahn, T | - |
dc.contributor.author | Yang, JY | - |
dc.contributor.author | Jeong, YS | - |
dc.contributor.author | Rhew, JH | - |
dc.contributor.author | Park, SJ | - |
dc.contributor.author | IRIS-DES Investigators | - |
dc.date.accessioned | 2013-04-22T22:13:35Z | - |
dc.date.available | 2013-04-22T22:13:35Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 1941-7640 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/7804 | - |
dc.description.abstract | BACKGROUND: It remains unclear whether there are differences in the safety and efficacy outcomes between everolimus-eluting stents (EES) and sirolimus-eluting stents (SES) in contemporary practice.
METHODS AND RESULTS: We prospectively enrolled 6166 consecutive patients who received EES (3081 patients) and SES (3085 patients) between April 2008 and June 2010, using data from the Interventional Cardiology Research In-Cooperation Society-Drug-Eluting Stents Registry. The primary end point was a composite of death, nonfatal myocardial infarction (MI), or target-vessel revascularization (TVR). At 2 years of follow-up, the 2 study groups did not differ significantly in crude risk of the primary end point (12.1% for EES versus 12.4% for SES; HR, 0.97; 95% CI, 0.84-1.12, P=0.66). After adjustment for differences in baseline risk factors, the adjusted risk for the primary end point remained similar for the 2 stent types (HR, 0.96; 95% CI, 0.82-1.12, P=0.60). There were also no differences between the stent groups in the adjusted risks of the individual component of death (HR, 0.93; 95% CI, 0.67-1.30, P=0.68), MI (HR, 0.97; 95% CI, 0.79-1.18, P=0.74), and TVR (HR, 1.10; 95% CI, 0.82-1.49, P=0.51). The adjusted risk of stent thrombosis also was similar (HR, 1.16; 95% CI, 0.47-2.84, P=0.75). CONCLUSIONS: In contemporary practice of percutaneous coronary intervention procedures, the unrestricted use of EES and SES showed similar rates of safety and efficacy outcomes with regard to death, MI, sent thrombosis, and TVR. Future longer-term follow-up is needed to better define the relative benefits of these drug-eluting stents. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01070420. | - |
dc.language.iso | en | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Angioplasty, Balloon, Coronary | - |
dc.subject.MESH | Cardiovascular Agents | - |
dc.subject.MESH | Chi-Square Distribution | - |
dc.subject.MESH | Coronary Thrombosis | - |
dc.subject.MESH | Drug-Eluting Stents | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Kaplan-Meier Estimate | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Myocardial Infarction | - |
dc.subject.MESH | Proportional Hazards Models | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Prosthesis Design | - |
dc.subject.MESH | Registries | - |
dc.subject.MESH | Republic of Korea | - |
dc.subject.MESH | Risk Assessment | - |
dc.subject.MESH | Risk Factors | - |
dc.subject.MESH | Sirolimus | - |
dc.subject.MESH | Time Factors | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Outcomes after unrestricted use of everolimus-eluting and sirolimus-eluting stents in routine clinical practice: a multicenter, prospective cohort study | - |
dc.type | Article | - |
dc.identifier.pmid | 22693347 | - |
dc.identifier.url | http://circinterventions.ahajournals.org/cgi/pmidlookup?view=long&pmid=22693347 | - |
dc.contributor.affiliatedAuthor | 탁, 승제 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1161/CIRCINTERVENTIONS.111.966549 | - |
dc.citation.title | Circulation. Cardiovascular interventions | - |
dc.citation.volume | 5 | - |
dc.citation.number | 3 | - |
dc.citation.date | 2012 | - |
dc.citation.startPage | 365 | - |
dc.citation.endPage | 371 | - |
dc.identifier.bibliographicCitation | Circulation. Cardiovascular interventions, 5(3). : 365-371, 2012 | - |
dc.identifier.eissn | 1941-7632 | - |
dc.relation.journalid | J019417640 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.