Cited 0 times in Scipus Cited Count

Structural limitations of currently available microcatheters and coils for endovascular coiling of very small aneurysms.

DC Field Value Language
dc.contributor.authorLim, YC-
dc.contributor.authorKim, BM-
dc.contributor.authorShin, YS-
dc.contributor.authorKim, SY-
dc.contributor.authorChung, J-
dc.date.accessioned2010-12-29T02:12:18Z-
dc.date.available2010-12-29T02:12:18Z-
dc.date.issued2008-
dc.identifier.issn0028-3940-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/888-
dc.description.abstractINTRODUCTION: Coil embolization for very small aneurysms (<3 mm in maximum diameter) has been considered a technically challenging method due to increased risk of potential aneurysm perforation during the procedure. We present our observations about the structural limitations of eight types of microcatheters and three types of detachable coils, and technical pitfalls in the coiling of very small aneurysms.



METHODS: The structures of each type of microcatheter and coil were carefully evaluated under a stereoscopic microscope. The evaluation the microcatheters was focused on the distance between the distal end of the distal marker and the tip of microcatheter. The evaluation of the coils was focused on the length of the detachment zone.



RESULTS: With markers of the coil delivery systems and microcatheters aligned under fluoroscopic visualization according to the manufacturers' recommendations, the stiff detachment zones protruded approximately 0.2-1 mm from the microcatheter tip. The lengths of the detachment zone, which is known to be a stiff segment, of the currently available coils were approximately 0.5-0.8 mm. The distance between the distal end of the distal markers of the microcatheters and the detachment zone of the coil ranged from approximately 1.2 to 2.8 mm.



CONCLUSION: To prevent rupture of very small aneurysms during coiling, the distal marker of the selected microcatheter should be carefully located near the aneurysm neck, considering all the structural characteristic of the currently available coils and microcatheters. Refinement of currently available devices may be essential to achieve safer coiling of very small aneurysms.
-
dc.language.isoen-
dc.subject.MESHAneurysm, Ruptured-
dc.subject.MESHAngioplasty-
dc.subject.MESHEmbolization, Therapeutic-
dc.subject.MESHEquipment Design-
dc.subject.MESHEquipment Failure Analysis-
dc.subject.MESHFluoroscopy-
dc.subject.MESHHumans-
dc.subject.MESHIntracranial Aneurysm-
dc.titleStructural limitations of currently available microcatheters and coils for endovascular coiling of very small aneurysms.-
dc.typeArticle-
dc.identifier.pmid18283447-
dc.contributor.affiliatedAuthor신, 용삼-
dc.contributor.affiliatedAuthor김, 선용-
dc.contributor.affiliatedAuthor정, 준호-
dc.type.localJournal Papers-
dc.identifier.doi10.1007/s00234-008-0365-y-
dc.citation.titleNeuroradiology-
dc.citation.volume50-
dc.citation.number5-
dc.citation.date2008-
dc.citation.startPage423-
dc.citation.endPage427-
dc.identifier.bibliographicCitationNeuroradiology, 50(5). : 423-427, 2008-
dc.identifier.eissn1432-1920-
dc.relation.journalidJ000283940-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Neurosurgery
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse